SPECIFICATIONS
XPLORER
400
POWER QUALITY ANALYZER
www.dranetz.com
Take Dranetz PQ Monitoring to the Air or Sea
with 400Hz Capability!
XPLORER 400
®
MEASURED PARAMETERS
(4) Differential Voltage: 512 s/c @50/60Hz (1MHZ for High Speed
Transient), 16 bit resolution. 64 S/C @400Hz
0-1000Vrms, AC/DC, ±0.1 % reading, <40V ±0.5%FS
IEC 61000-4-30 Class A: 60-1000Vrms, ±0.1 % of Udin, range of
10% ~ 150% of Udin. (50/60Hz only)
Transients - High Speed: 10-2000Vpk, +/- 10% of reading,
+/- 0.5%FS
Transients: 0-1500Vpk, ±0.2 % of Udin
(4) Current (rms): 512 s/c (1MHZ for HS Trans.), 16 bit resolution.
64 S/C @400Hz
Range probe dep., AC/DC, +/- 0.1% reading +/- 0.05% FS
Transients - High Speed: Range probe dep., 10% of Reading
+/- 0.5%FS
Transients: Range probe dep., ±0.2 % of Udin
Frequency:
42.5-69Hz, +/- 0.01Hz, 380-420Hz +/- 0.1Hz
CALCULATED PARAMETERS
Power/Energy - 1 Second sampling
Real Power (W) - P: meets 0.2S requirements, range probe dep.
Apparent Power (VA) - S: meets 0.2S requirements, range probe dep.
Reactive Power (var) - Q: meets 0.2S requirements, range probe dep.
Power Factor (W/VA) -”true” 1 to 0 to -1
Displacement PF 1 to 0 to -1
Demand (in W): meets 0.2S requirements, range probe dep.
Energy (in Wh): meets 0.2S requirements, range probe dep.
Distortion - 200ms, 3 sec, 10 min windows
Vthd: 0-100%, +/- 5% for V>=1% Vnom,
V Ind Harm: DC, 2-127 @50/60Hz, 2-15 @400Hz, +/- 5% for V>=1% Vnom
Ithd: 0-100%, +/- 5% for I>=1% Vnom,
I Ind Harm: DC, 2-63
@50/60Hz, 2-15 @400Hz,
+/- 5% for I>=1% Vnom
Misc.
Pst - 10 minutes: 0.2-10, +/- 0.05 @ Pst=1 (50/60Hz only)
Plt - 2 hours: 0.2-10, +/- 0.05 @ Pst=1 (50/60Hz only)
EASE OF USE FEATURES
Automatic Setups
Pre-programmed monitoring modes
AnswerModules
®
- Sag/Dip Directivity, PF Cap, Motor (50/60Hz only)
Dashboards - PQ, Demand & Energy
Simultaneous PQ, Demand & Energy
Mini Report, Screen Snapshots
STANDARDS COMPLIANCE (50/60Hz only)
Power Quality
IEC 61000-4-30 Class A: Edition 2 (2008)
IEEE 1159: 2009
Power
IEEE 1459: 2000
Harmonics
IEC 61000-4-7 Class 1: Edition 2 (2008)
IEEE 519: 2014
Voltage Flicker
IEC 61000-4-15: Edition 2 (2010)
IEEE 1453: 2011
Compliance/Testing
EN 50160: 2010
GENERAL SPECIFICATIONS
Size (10”w x 8”h x 2.75”d) (25.4cm x 20.3cm x 7.00 cm)
Weight: 1.9 kg, 4.3lbs
Operating temperature: 0 to 50 deg C
Storage temperature: -20 to 60 deg C
Humidity: 10-90% non condensing
Clock accuracy and resolution
Internal: +/- 1 sec/day at 25deg C
NTP: +/-10 msec
GPS: +/-1 msec
AC Adapter: 90-264Vac 50/60Hz
Battery capacity and charge time: 2.5 hours run time on full charge
(3 hour charge time)
Memory size: 4GB
Display: 7” WVGA color graphic, icon based touch LCD, LED Backlit
Languages: English, German, Spanish, French, Italian, Swedish, Finnish,
Polish, Chinese (traditional and simplified), Thai, Korean
COMMUNICATIONS
Ethernet, 802.11 b/g/n Wireless
USB On the Go
Bluetooth via USB adapter
VNC remote control
Android
®
& Apple
®
App
J01-RevA
Dranetz HDPQ Xplorer 400 Brochure.indd 1-2 1/7/15 5:38 PM